Systems overview

How the parts of an EV conversion connect

One drawing of the whole HV and LV system, then a sheet per subsystem. Step each drawing through its states: off, precharge, contactors closed, drive, regen, charging.

Whole vehicle: HV, LV and charge paths through every state

This figure is interactive and needs JavaScript. The text description below covers the same content.

Step from key-off through precharge, drive, regen and both kinds of charging. Layers switch on the CAN backbone and the HVIL loop.
Text description

The traction pack (with its service disconnect and BMS) feeds an HV junction box. Inside it, the main fuse and main positive contactor sit on the positive rail with the precharge relay and resistor in parallel, and the main negative contactor sits on the negative rail. The HV bus then feeds the inverter and motor, the DC-DC converter, and the onboard charger. A separate pair of DC fast-charge contactors connects the charge inlet straight to the HV bus.

Off: everything open, only the 12 V battery is live. Wake: the 12 V system powers the VCU and BMS, which check the interlock loop and isolation. Precharge: main negative and precharge close and the bus charges through the resistor. Ready: main positive closes, precharge opens, the DC-DC starts charging the 12 V battery. Drive: power flows pack to inverter to motor. Regen: the motor drives the inverter and current flows back into the pack. AC charge: the inlet feeds the onboard charger, which charges the pack through the main contactors. DC fast charge: the DC contactors close and the station charges the pack directly. Interlock open: the contactors drop out and the DC link is actively discharged.

Subsystem sheets

9 sheets · all interactive
  1. 01 Battery pack, modules, and BMS Cells in series set the voltage, cells in parallel set the capacity. The BMS watches every series group and holds the whole string to its weakest cell. 2 fig.
  2. 02 Fuses, pyro fuse, and the service disconnect The main fuse clears a short, a pyro fuse cuts on a crash signal, and the service disconnect splits the pack so nobody works on the full string. 1 fig.
  3. 03 HV switching: contactors and precharge One contactor on the positive side, one on the negative, and a precharge path that charges the inverter capacitor before the main closes. 1 fig.
  4. 04 Motor and inverter Six switches turn the DC bus into three phases. Sine PWM and space-vector PWM are two ways to time them, and the same bridge runs backwards for regen. 1 fig.
  5. 05 DC-DC converter: HV to 12 V The alternator is gone. An isolated converter takes pack voltage down to about 14 V to run the 12 V system and keep its battery charged. 1 fig.
  6. 06 AC charging: J1772 and the onboard charger The wall box switches AC and advertises a current limit on the pilot. The onboard charger turns that AC into pack DC. States A to F tell both sides what is going on. 2 fig.
  7. 07 CAN bus Two wires, driven differentially, terminated at both ends. Every frame carries an ID that is also its priority, and bit stuffing keeps every node in sync. 2 fig.
  8. 08 Thermal: coolant loops, pumps, heater, and chiller A drive-unit loop dumps heat to a radiator. A battery loop is kept in a narrow window: heated in the cold, chilled from the AC system on a fast charge. 1 fig.
  9. 09 HV wiring, HVIL, and isolation monitoring The HV bus floats: neither rail is bonded to the chassis. An interlock loop proves every connector is mated, and an isolation monitor measures leakage to chassis. 2 fig.