System 09
HV wiring, HVIL, and isolation monitoring
The HV bus floats: neither rail is bonded to the chassis. An interlock loop proves every connector is mated, and an isolation monitor measures leakage to chassis.
- Sheet
- 09 / 09
- Figures
- 2
- Interactive
- Yes
- Related notes
- 0
Anything above 60 V DC is voltage class B under ISO 6469-3: high enough to need protection against direct contact. A conversion pack is far above that. The protection comes in layers: cable and connectors you cannot touch, a bus that floats free of the chassis, a loop that proves every connector is mated, and a monitor that notices when the float is lost.
HV wiring
- Orange means HV. Use orange-jacketed HV cable for every class B conductor, so anyone working on the car knows what not to cut.
- Rated twice. Size the cable for current (ampacity at the temperature it will see) and buy it with a voltage rating above full-charge pack voltage. The cable tab handles the current side.
- Shielded, shield to chassis. HV cable from the inverter carries fast switching edges. A braided shield bonded to the component housings and chassis at the connectors keeps that noise off the CAN and sensor wiring.
- Route for abrasion. Clamp it, sleeve it where it crosses edges, keep it away from exhaust-hot and moving parts, and leave no slack loops that can chafe.
- Touch-safe connectors and covers. No exposed lugs. Finger-proof connectors, covered bus bars, and HV warning labels on every enclosure that holds class B parts.
- Bond every housing. Pack, junction box, inverter, DC-DC, charger, compressor and heater housings are all bonded to the chassis with low-resistance straps. If an HV conductor ever touches a housing, it touches chassis, and the isolation monitor sees it.
The interlock loop (HVIL)
A low-voltage signal loop runs in series through an interlock pin pair in every HV connector and cover. The controller drives the loop and checks that the signal comes back. Unplug anything, lift a cover, or pull the service disconnect, and the loop opens.
- Break first, make last. The interlock pins are shorter than the HV pins. Pulling a connector opens the interlock before the HV pins separate, so the contactors are already opening and the HV pins never break load current.
- Then discharge. With the contactors open, the inverter actively discharges its DC-link capacitor. OEMs typically target under 60 V within a few seconds. A passive bleed resistor is the slower backstop if active discharge fails.
- Latch it. When the loop closes again, the contactors stay open until the next key cycle and a full precharge.
HVIL: the low-voltage loop through every HV connector
This figure is interactive and needs JavaScript. The text description below covers the same content.
Text description
A low-voltage signal loop runs in series through a short-pin pair in every HV connector and cover. Each pair breaks before the HV pins do when the connector is pulled.
The controller drives a signal around the loop and checks it comes back. If the loop opens, the contactors open and the inverter discharges the DC link, before anyone can touch a live pin.
Isolation monitoring
The HV bus floats: neither rail is connected to the chassis. One insulation fault, say chafed cable against a bracket, connects one rail to the chassis and nobody feels anything. But the protection is now gone. Touch the other rail and the chassis, and current flows through the body and back through the fault.
- Measure it continuously. An insulation monitoring device (IMD) measures resistance from each rail to chassis while the car runs. Many conversion BMSs and VCUs accept a standalone IMD on CAN or a fault line.
- Read it in Ω/V. Divide the isolation resistance by the maximum working voltage. FMVSS 305 and UN ECE R100 require at least 100 Ω/V for DC circuits and 500 Ω/V for AC circuits, unless they are otherwise protected. At 100 Ω/V, single-fault touch current tops out near 10 mA.
- Warn early. Set the warning above the legal floor so a slowly degrading cable shows up as a warning long before it becomes a fault.
- Y-capacitors count too. EMI filter capacitors from each rail to chassis store energy that a touch can discharge. Regulations limit that energy; keep the total Y-capacitance in mind when adding filtered components.
Isolation monitoring: leakage to chassis in Ω/V
This figure is interactive and needs JavaScript. The text description below covers the same content.
Text description
The HV bus is floating: neither rail is connected to the chassis. An isolation monitor measures the resistance from each rail to chassis.
That resistance divided by the maximum working voltage gives ohms per volt. FMVSS 305 and UN ECE R100 require at least 100 Ω/V for DC circuits and 500 Ω/V for AC circuits unless they are otherwise protected. A single fault does not shock anyone, but it removes the isolation that stops a second fault from doing so.