Fuses, pyro fuse, and the service disconnect
The main fuse clears a short, a pyro fuse cuts on a crash signal, and the service disconnect splits the pack so nobody works on the full string.
- Sheet
- 02 / 09
- Figures
- 1
- Interactive
- Yes
- Related notes
- 1
A charged pack cannot be switched off. The cells hold their voltage whether anything is connected or not. Protection devices limit what a fault can do and let a person split the pack safely. None of them makes the cells safe.
Three devices, three jobs
- Main fuse: clears a short. It sits on the pack output, sized to protect the smallest conductor it feeds. At many times its rating it melts in milliseconds. Near its rating it can take minutes, or never open at all.
- Pyro fuse: cuts on a signal. A small charge, fired by the crash or airbag controller, severs the conductor in milliseconds without waiting for fault current. It is one-shot. OEM packs often have one; conversions often do not.
- Service disconnect (MSD): splits the string. A pull-out plug, usually mid-pack and usually with its own fuse. Pulling it breaks the series string so nobody works on the full pack voltage. On most OEM packs it also breaks the interlock loop first.
Pack protection: service disconnect, main fuse, pyro fuse
This figure is interactive and needs JavaScript. The text description below covers the same content.
Text description
The pack is drawn as two halves joined by a manual service disconnect (MSD), usually with its own fuse. The main fuse sits on the positive output, and a pyrotechnic fuse can cut the conductor on a signal from the airbag or crash controller.
Scenarios: normal, short at the inverter (main fuse clears), overload (the fuse is too slow; the BMS and inverter must limit current), crash signal (pyro fuse cuts), and MSD pulled (each half keeps about half the pack voltage). The log-log time-current curve is an illustrative fast DC fuse, not a real part; the shaded zone above the contactor break rating is where the fuse, not the contactor, must clear the fault.
Fuse versus contactor
A contactor can break normal load current many times. It can break a fault only up to its rated break current, often a one-time rating at a stated voltage. A short circuit on a big pack can be far beyond that, and an arc held across opening contacts is how a contactor fails. Above the contactor's break rating, the fuse has to clear the fault. That is why the fuse must be fast at high current and DC-rated at the full pack voltage.
Sizing checks
- DC voltage rating first. A DC arc does not cross zero the way AC does. The fuse needs a DC rating at or above the full-charge pack voltage. Automotive blade and ANL fuses are low-voltage parts.
- Current rating from the cable. The fuse protects the cable, so size it below the cable's ampacity and above normal peak current. The fuse tab and cable tab run that pairing.
- Interrupting rating. The fuse must be able to clear the pack's prospective short-circuit current, which can be tens of kiloamps on a low-resistance pack.
- Overload is the BMS's job. Sustained overcurrent at 1.2 to 2× rating is handled by the BMS current limit and the inverter derating, not by waiting for a fuse.
Before you work on it
- Open the contactors and pull the MSD. Then measure, with a meter rated for the voltage, across every point you are about to touch. Each half of the pack is still live.
- Wait for the DC link to discharge and confirm it reads near zero.
- Keep the MSD in your pocket so nobody refits it while you work.
The fuse curve in the figure is illustrative, not a real part. Read clearing times and I²t from the datasheet of the fuse you buy. More on sizing in the pack planning note.