A traction pack is a lot of identical cells wired two ways at once. Cells in parallel form a group that behaves like one bigger cell. Groups in series stack up the voltage. Everything else in the pack — bus bars, modules, fuses, the BMS — follows from those two numbers.

Series sets voltage, parallel sets capacity

  • S is the voltage. Pack voltage is the series count times cell voltage. 96 NMC groups at 3.65 V nominal is about 350 V, 403 V full and 288 V empty. The inverter, DC-DC and charger all have to accept that whole range, not just the nominal figure.
  • P is the capacity and the current. Amp-hours and peak current both scale with the parallel count. Each cell in a group shares the group current, so more cells in parallel means less current per cell.
  • Energy is the product. kWh = nominal volts × amp-hours ÷ 1000. Work the target from range first: the battery tab and the pack planning note walk through it.
  • Chemistry moves every number. NMC runs about 3.0 to 4.2 V per cell, LFP about 2.5 to 3.65 V. The same voltage target needs roughly 15% more LFP groups in series.

Pack builder: cells, series groups, modules

This figure is interactive and needs JavaScript. The text description below covers the same content.

Pick a chemistry, cell capacity, and the series, parallel and module counts. Voltage follows the series count; capacity and current follow the parallel count.
Text description

Cells are first paralleled into groups (the P count), then the groups are wired in series (the S count) and split into modules. Pack voltage is S times cell voltage; capacity in amp-hours is P times cell capacity; energy is the product.

The readout gives nominal, full and empty pack voltage for the chosen chemistry, capacity, energy, and the number of voltage taps a BMS needs (one per series group, plus one).

Large packs are drawn as a representative subset: the first modules, an ellipsis with the count left out, and the last module; groups inside a module are shortened the same way. Uneven module splits are shown as they are, for example 2×13s + 5×12s.

Modules

Packs are split into modules so they can be built, handled and replaced in pieces. Keeping each module at or below 60 V DC keeps it out of voltage class B while it is out of the pack, which makes assembly and storage much simpler. Check how the series count divides: uneven modules are possible, but every module type is another part to stock and another BMS harness to wire.

What the BMS actually does

  • One voltage tap per series junction. A pack of S groups needs S + 1 sense wires. Parallel cells in a group share one voltage, so the BMS measures groups, not individual cells.
  • Temperature at enough points. Charge and discharge limits depend on cell temperature. A few thermistors per module is common.
  • It sets the limits, other boxes obey them. The BMS publishes allowed charge and discharge current, usually over CAN. The charger and inverter have to read those limits; the BMS opens the contactors only as a last resort.
  • The string is only as good as one group. Charging stops when the highest group is full. Discharging stops when the lowest is empty. Any spread between groups is capacity the pack cannot use.

BMS: cell taps, spread, and passive balancing

This figure is interactive and needs JavaScript. The text description below covers the same content.

Push one series group out of line and see the BMS hold the whole string to it. Turn balancing on to bleed the high groups.
Text description

A row of series groups with a BMS tap between each. Each bar shows one group's voltage. Charging stops when the highest group reaches its maximum, and discharging stops when the lowest group reaches its minimum, so the usable capacity of the whole string is set by the weakest and the most-charged groups.

Passive balancing switches a small resistor across the high groups and burns off their extra charge as heat until they match the rest.

The figure runs the simulation fast. The real-time readout divides the charge spread by the chosen bleed current, so a few percent on a 5 Ah cell takes hours.

Balancing

Passive balancing switches a small resistor across each high group and turns its extra charge into heat until it matches the rest. Bleed currents are small — tens to a couple of hundred milliamps is typical (the Dilithium BMSC note cites 170 mA, for example). On a large-capacity cell that corrects a few percent per session, not a badly mismatched pack in one night. Active balancers move charge between groups instead of burning it, at more cost and complexity.

  • Voltage spread understates charge spread. In the flat middle of the curve, especially on LFP, groups several percent apart in charge sit only a few millivolts apart. Balancing near the top of charge, where the curve is steep, is where the BMS can see the difference.
  • Match cells before building. Balancing keeps a good pack good. Start with groups at the same voltage and similar capacity.
  • A wrecked OEM pack keeps its cells, not its brain. Reusing salvage modules usually means a standalone conversion BMS wired to the module sense harness.