System 04

Motor and inverter

Six switches turn the DC bus into three phases. Sine PWM and space-vector PWM are two ways to time them, and the same bridge runs backwards for regen.

Sheet
04 / 09
Figures
1
Interactive
Yes
Related notes
0

The pack makes DC. An AC traction motor wants three phases whose frequency follows shaft speed and whose voltage follows load. The inverter builds those phases by switching the DC bus on and off, tens of thousands of times a second, through six power switches.

The bridge

  • Three half-bridges. Each phase (U, V, W) has a high-side switch to DC + and a low-side switch to DC −. One of the pair is on at a time; turning both on shorts the DC link, so the controller inserts a short dead time between them.
  • Antiparallel diodes. Each switch has a diode across it. Motor windings are inductive: when a switch opens, current keeps flowing and the diode carries it. In regen those diodes, and the switches, carry current back to the DC link.
  • DC-link capacitor. The switching current comes from the capacitor across the bridge, not straight from the pack cables. It is the capacitor the precharge circuit has to charge.

Sine PWM and space-vector PWM

Averaged over one switching period, each phase output sits at a voltage set by its duty cycle. Vary the duties sinusoidally and the motor sees three sine waves. Sine PWM does that by comparing each phase reference with a triangle carrier. It runs out of headroom when the reference peak reaches half the DC link (m = 1).

The motor only sees line-to-line voltage, so the same offset can be added to all three phases without changing anything it feels. Space-vector PWM does exactly that: in each of six sectors it uses the two switch states next to the reference vector plus the zero states (all low or all high). The result fits about 15% more fundamental voltage inside the same DC link, up to m = 2/√3 ≈ 1.155. Most modern drives use it or an equivalent.

Inverter: six switches, three phases, sine PWM vs space-vector PWM

This figure is interactive and needs JavaScript. The text description below covers the same content.

Watch the switch states and the voltage space vector rotate, or pause and scrub the electrical angle. Change modulation, frequency and mode; flip to regen to reverse the power flow.
Text description

A three-phase bridge: three half-bridges, each with a high-side and low-side switch, across the DC link. Each phase output connects to one motor winding. Only one switch in each half-bridge is on at a time.

Sine PWM compares each phase reference with a triangle carrier. Space-vector PWM picks the two active switch states that bracket the reference vector, plus the zero states, in each of six sectors. It reaches about 15% more fundamental voltage from the same DC link.

Motor types you meet in conversions

  • Permanent-magnet synchronous (PMSM, IPM). Most current OEM drive units (Tesla Model 3 and Y rear units, Leaf, Bolt, most hybrids). The rotor has magnets, so the inverter must know rotor position precisely, usually from a resolver, to put current at the right angle.
  • Induction. Older Tesla units and many industrial motors. No magnets; the inverter controls slip. It needs speed feedback (an encoder) rather than absolute position, and spinning it unpowered generates nothing.
  • Back-EMF is real. A permanent-magnet motor generates voltage whenever it turns. Tow or coast a PMSM car fast enough with the inverter off and that voltage can exceed the DC link. Field weakening keeps it in check while the inverter is running.

Regen

The same bridge runs backwards. The controller shifts the phase current so it opposes the motor's voltage, the motor becomes a generator, and average DC current flows into the pack. How much is allowed is the BMS's call, not the inverter's: regen is a charge current, and a cold or full pack accepts very little. Pass the BMS charge-current limit to the inverter over CAN and let it taper regen.

Sizing checks

  • DC link voltage sets top speed. Motor back-EMF rises with speed. When it reaches what the inverter can produce from the DC link, torque falls off. A lower-voltage pack moves that corner down.
  • Current sets torque. Inverter phase-current rating and motor current limit decide peak torque. Pack and fuse have to supply the matching DC current: roughly power divided by pack voltage.
  • Work it through. The motor tab in the toolbox estimates power from weight, grade and acceleration.

Waveforms in the figure use a carrier only twelve times the fundamental so the triangles are visible. Real drives switch at 5 to 20 kHz, hundreds of carrier periods per electrical cycle.